Nassau 2-2-2-4 SER WG Aluminum Service entrance Cable Wire 600V Applications Aluminum service entrance cable is mainly used in branch circuits and panel feeders. The voltage rating for this electrical cable is 600 volts. Aluminum service entrance cables are designed for use in adverse weather conditions, with operating temperatures being 90°C in both wet and dry locations. However, type R cables can operate at 60°C when terminated to equipment for circuits rated at 100 Amps or less or if it is marked for 14 gauge through 1 gauge conductors. In addition, SER cables can operate at 70°C when the electrical cable is terminated to equipment in circuits rated over 100 Amps or when marked for conductors larger than 1 gauge. Images are for reference only See Product Specifications Please order carefully no returns are accepted. Conductor Aluminum type R cable has compact strand soft drawn 8000 series aluminum conductor, per ASTM B-801. The conductor is the electrode in the cable and is responsible for transmitting electric current. jacket: The cable jacket used in its design is Polyvinyl Chloride (PVC). The jacket protects the inner components of the cable from potentially damaging external forces. PVC is robust and resistant to oil, sunlight, water, flames, acids, chemicals, radiation, impact, abrasion, and weather changes. Sequential footage markings that help the user identify the appropriate length during installation are noted on the cable jacket. Insulation Aluminum SER cable has a type XHHW-2 cross-linked polyethylene (XLP) insulation. The conductors are cabled together with bare aluminum ground and covered with reinforced binder tape. For color code, see table B in the technical section. Product Specifications Insulated Cond(s) Size AWG: 2 Bare Conductor Size AWG: 4 Nominal O.D. Inches: 0.863 Approx. Weight lbs/1000FT: 346 lbs Ampacity at 90°C: 100 Amps Ampacity in dwelling: 100 Amps 1-1-1-3 SER Copper 2-2-2-4 SER Copper 3-3-3-5 SER Copper 1/0-1/0-1/0-2 SER Copper 2/0-2/0-2/0-1 SER Copper 3/0-3/0-3/0-1/0 SER Copper Buying Options Buying Options Buying Options Buying Options Buying Options Buying Options Customer Reviews 5.0 out of 5 stars 1 5.0 out of 5 stars 23 4.6 out of 5 stars 21 5.0 out of 5 stars 3 4.5 out of 5 stars 2 5.0 out of 5 stars 2 Size AWG: 1-1-1-3 2-2-2-4 3-3-3-5 1/0-1/0-1/0-2 2/0-2/0-2/0-1 3/0-3/0-3/0-1/0 Weight per 1,000 ft: 1117 lbs 887 lbs 719 lbs 1382 lbs 1713 lbs 2129 lbs Outside Diameter: 1132 mils 984 mils 910 mils 1235 mils 1342 mils 1462 mils Conductors: Annealed Soft Copper Annealed Soft Copper Annealed Soft Copper Annealed Soft Copper Annealed Soft Copper Annealed Soft Copper Stranding: Phase & Neutral Conductors: 19 Phase & Neutral Conductors: 7 Phase & Neutral Conductors: 7 Phase & Neutral Conductors: 19 Phase & Neutral Conductors: 19 Phase & Neutral Conductors: 19 Stranding: Equipment Ground Conductor: 7 Equipment Ground Conductor: 7 Equipment Ground Conductor: 7 Equipment Ground Conductor: 19 Equipment Ground Conductor: 19 Equipment Ground Conductor: 19 Insulation: XLPE XLPE XLPE XLPE XLPE XLPE Jacket: PVC PVC PVC PVC PVC PVC